Wilchester HVAC Balance Audit

Latest Magicplan · 2,547.87 ft² · room loads + vent-by-vent measurements
Design airflow—
Measured vents—
Modeled load—
Rooms off target—
StatusSETUP
Autosave on
MEASUREMENTS
Existing readings are preserved as the Before baseline.

Annotated HVAC layout

Red = supply · blue = return
RoomArea usedSupply ducts markedReturn marked
Master Bedroom238.88 ft²2 × 6″—
Master Bathroom88.06 ft²1 × 4″—
Primary WC25.28 ft²1 × 4″—
Primary Closet26.33 ft²1 × 4″—
Boy Bedroom146.72 ft²1 × 8″—
Hall Bathroom56.27 ft² incl. tub alcove1 × 4″—
Girls Bedroom166.04 ft²1 × 8″—
Office129.70 ft²1 × 8″—
Great Room31′ × 15′ · 465 ft²1 × 8″—
Entry Hall6′ × 13′ · 78 ft²1 × 6″—
Bedroom HallOutside Hall Bathroom—1 × 18″ return
Kitchen21′ × 8′ · 168 ft²1 × 6″—
Breakfast Room10.5′ × 9′ · 94.5 ft²1 × 8″—
Laundry Room8′ × 9′ · 72 ft²1 × 6″—
Powder Room3′ × 5′ · 15 ft²1 × 4″—
Pantry7′ × 6′ · 42 ft²1 × 4″—
Play Room12′ × 13′ · 156 ft²1 × 8″1 × 8″ return

The two blue return marks are tracked in the Returns section. Wall lengths and window areas are plan-based estimates and remain editable.

Field table · rooms & supply vents

Latest floor-plan rooms, areas, dimensions, estimated window areas, and AC-run distances are preloaded.
Tap a room row to select it. The selected room receives “+ Vent”.
Room / ventArea
ft²
Room
temp °F
Door
ΔP Pa
Return pathDuct
Ø in
Run to AC
ft
Velocity
measured at
Register
W in
Register
H in
Free areaAnemometer
FPM
Est.
CFM
Room total
CFM
Target
CFM
Δ CFMActionNotes

Choose Grille face for an average reading across the grille. Choose Duct center after removing the grille; this uses round-duct area and estimates average velocity at 90% of the center reading. Distances and window areas are floor-plan estimates. Your existing measurements are preserved.

Latest floor-plan inventory · all 24 Magicplan spaces
Plan spaceArea ft²Printed dimensionsHVAC treatment
Primary bedroom238.8816′ 1¼″ × 16′ 9¼″Separate balance row
Primary bathroom88.0616′ 2″ × 5′ 5¼″Separate balance row
Primary WC25.284′ 10¼″ × 5′ 2½″Separate balance row
Primary closet A26.335′ ¾″ × 5′ 2½″Nested with primary suite
Primary closet B28.475′ 5¾″ × 5′ 2½″Nested with primary suite
Boy bedroom146.7212′ 2″ × 12′ ¾″Separate balance row
Boy closet25.1011′ ¾″ × 2′ 3¼″Nested with bedroom
Shared bathroom31.856′ 7¾″ × 4′ 9½″Separate balance row
Tub alcove24.425′ ½″ × 4′ 10″Nested with shared bath
Bath wall segment A0.715′ 4¼″ × 3½″Non-conditioned partition
Bath wall segment B0.603′ 10¼″ × 2″Non-conditioned partition
Hall / circulation115.2115′ 1¾″ × 22′ 6½″ overallSeparate balance row
Girls’ closet24.118′ 1¼″ × 3′ 1″Nested with bedroom
Girls’ bedroom166.0411′ 10¾″ × 16′ 4″Separate balance row
Hall closet17.185′ 10″ × 2′ 11¼″Nested with hall
Study129.7011′ 7¾″ × 11′ 1½″Separate balance row
Fireplace / chase20.83Not printedNon-conditioned chase
Living / kitchen621.6039′ 3½″ × 21′ 1½″ overallSeparate balance row
Breakfast / dining88.919′ 1¼″ × 9′ 9¼″Separate balance row
Laundry room77.278′ 8¾″ × 8′ 10¼″Separate balance row
Powder closetNot printedNot printedNested with powder room
Powder room16.75Approx. 3′ 6¼″ × 4′ 4″Separate balance row
Playroom closetNot printedNot printedNested with playroom
Playroom290.3514′ 1¼″ × 23′ 3¾″Separate balance row

Return-air measurements

Bedroom Hall + Playroom returns
Choose where you measured velocity, then enter the matching dimensions and FPM.
LocationDuct
Ø in
Run to AC
ft
Velocity
measured at
Grille
W in
Grille
H in
Free areaAnemometer
FPM
Est.
CFM
Filter grilleNotes
Return airflow not measured yetChoose a measurement method and enter its required values.

Grille face uses average face velocity × grille area × free-area factor. Duct center uses the round duct diameter and estimates average velocity at 90% of the center reading.

System & house

Equipment confirmed from the June and September 2023 labels.
OUTDOOR ACAmerican Standard Silver 14 · 5 ton4A7A4060N1000BA · 60,000 BTU/h nominal · single-stage R-410A · manufactured 09/2023
FURNACE / BLOWERAmerican Standard S8B1 · 100,000 BTU/h inputS8B1C100M5PSCBA · 80% AFUE · 4–5 ton · 9-speed constant-torque blower · manufactured 06/2023
Blower setting still needs verificationThe equipment confirms a 5-ton system, but not which cooling-speed tap is active. At 350 CFM/ton the target is 1,750 CFM; at 400 CFM/ton it is 2,000 CFM. Record the board setting below or enter a measured blower CFM.
Advanced room load inputs · wall/window exposures

North is down on your floor plan: ↓ N · ↑ S · ← E · → W. Window fields are glass area in ft².

RoomCeil
ft
Wall NWall EWall SWall WWin NWin NEWin EWin SEWin SWin SWWin WWin NWPeopleWattsKitchenAttic?WallAtticGlassShade

Analysis

What to fix before and during balancing.

Results & backup

Readable tables update with the selected measurement set.